Version 1.0
Melting Point
Apparatus SMP40
Instructions for use
automatic melting point
SMP40
Dynalab Corp.
350 Commerce Drive
Rochester, NY 14623
Tel: 585-334-2060 800-828-6595
Fax: 585-334-0241
www.dynalabcorp.com
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - Apparatus SMP40

Version 1.0Melting PointApparatus SMP40Instructions for useautomatic melting pointSMP40Dynalab Corp. 350 Commerce Drive Rochester, NY 14623Tel: 585-3

Seite 2

1 Selecting an Alphanumeric Entry Field opens the text keypad interface.2 The alphanumeric entry field can be populated with letters (Abc), numbers

Seite 3 - 3. General Description

1 Selecting a Date Entry Field opens the date keypad interface.2 The date entry field is displayed in the format specified in the User Settings menu

Seite 4

105.2.6 Drop Down List Field1 Selecting a Drop Down List Field displays the options available for that field.2 Arrows keys may be displayed to in

Seite 5

116.1 Creating a New MethodIn the Measurement menu screen touch the “Create a new measurement” section of the screen.1 Enter a sample name for the

Seite 6 - 4. Preparation for Use

6.2 Preset MethodsIn the Measurement menu screen touch the “Use a preset from the library” section of the screen.121 In the preset methods screen se

Seite 7 - Controls

8 The option of saving this new method as a new preset method will be given if the sample name has been changed. Select “Yes” to save the method for

Seite 8

7. Performing Melt DeterminationsOnce the analysis method and sample information have been entered into the SMP40 software the instrument will display

Seite 9

153 The instrument status will change to “Heating” and the command toolbar options will change.4 The SMP40 will quickly heat the sample block to the

Seite 10

168 As the melt determination progresses the capillary tube melt status changes through:Solid: No changes have been detected in the samples physical

Seite 11

178. ResultsTouching the results section on the main menu screen will open the results menu. Two options are now available:View previous results: Dis

Seite 12 - 6. Setting up New Methods

1. Introduction 12. Safety Advice Before Use 13. General Description 1 3.1 Module Separation 2 3.2 Melting Point Determination 3 3.3

Seite 13

18Rename: The Rename action is used to change the Sample Name for the selected result.Delete: The Delete action is used to delete the selected result

Seite 14

194 The required option should be selected from the displayed list or alternatively enter the search criteria using the keypad that is displayed.5 W

Seite 15

208.1.2 Opening Results FilesWhen a melt determination is complete or a result file is opened, the screen will display the Report Screen.The report

Seite 16

218.1.3 Viewing VideosWhen a video record is accessed the Video Replay screen is displayed.Block temperature at specific timeSelected capillaryVideo r

Seite 17

221 To start the video replay press the play button () in the video replay controls. Once the play button has been pressed it will change to a pause

Seite 18

231 Select the capillary tube to which the manual event is to be added by pressing the relevant “Capillary selection” button.2 Select the timeframe

Seite 19 - 8. Results

24The melt determination report is updated with any manual events that are added and saved. An asterisk next to the event name is used to denote that

Seite 20

258.1.5 Deleting Result Files8.2 Re-use Result Parameters1 To delete individual results from the instruments memory highlight the result to be delet

Seite 21

269 File ManagementTouching the File Management section on the main menu screen will open the File Management menu. Two options are now available:Mana

Seite 22

9.1.1 Select All/Clear Selection1 Pressing the “Select All” button in the Manage Files toolbar will highlight all of the result files.2 If

Seite 23

1. IntroductionThank you for purchasing this piece of Stuart equipment. To get the best performance from the SMP40 please read these instructions care

Seite 24 - ❙) can be pressed to

3 Once the move action has been completed the files will no longer be available on the instrument so ensure that no further reprocessing of the resul

Seite 25

10 Settings and CalibrationTouching the Settings and Calibration section on the main menu screen will open the Settings and Calibration menu. There ar

Seite 26

Set time: The devices displayed time can be set using the time keypad interface.Set date: The devices displayed date can be set using the date keypad

Seite 27

10.2 Maintenance SettingsIn the Settings and Calibration menu screen touch the Change maintenance settings section of the screen. The Maintenance scr

Seite 28 - 9 File Management

For information on where to purchase suitable certified reference materials please contact us: [email protected]: +44 (0)1785 810433I

Seite 29

10.3.1 Current Calibration FactorThe current calibration factor shows the factor which is used to calculate the displayed block temperature on the dev

Seite 30

8 In the Select Calibration screen highlight the result file to be used for the first calibration point.9 Press the "Select result and continue

Seite 31 - 10 Settings and Calibration

15 The calibration screen is now updated to show the new calibration details. The Calibration history window will now update to display details of th

Seite 32

11. Maintenance & ServicingWARNING: Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicin

Seite 33

12. WarrantyStuart warrants this instrument (excluding the VGA touch screen) to be free from defects in material and workmanship when used under norma

Seite 34

3.1 Module SeparationFigure 1: SMP40 module separationThe SMP40 can be split into two separate modules using the split module release mechanism locate

Seite 35

Notes38

Seite 36

39Notes

Seite 38 - & Servicing

This product meets the applicable EC harmonized standards for radio frequency interference and may be expected not to interfere with, o

Seite 39 - 13. Specification

INSPECTION REPORT MODEL SMP40 ELECTRICAL SAFETY 1. Earth continuity  2. Insulation  3. Flash test  FUNCTIONAL 1. Indicator

Seite 40

3.2 Melting Point DeterminationThe capillary technique is a standard method for determining the melting point of a substance. In this method, thin gla

Seite 41

The SMP40 can accommodate up to three sample capillaries. For accurate melting point determinations it is recommended that three samples of the same m

Seite 42

5. Instrument and Software Controls5.1 Instrument Mains On/Off: This is a rocker type switch found on the left hand side o

Seite 43 - NEW DEC

When the instrument is first switched on the display will show “LOADING PLEASE WAIT” message. After 30 seconds the display will show the main menu scr

Seite 44 - INSPECTION REPORT

The command toolbar is located at the bottom of the screen in most menus within the software interface. The command toolbar will give the user either